FT-RF Guide to Circular Waveguide (International standard)

21/12/2021 Posted by: ft-rf.com.tw

FT-RF Guide to Circualar Waveguide 
EIAInsdie diameter (Round)Cutoff frequencyRecommended frequency
designation WCin cmin mmfor air-filled range for TE mode in GHZ
99225.184251.840.6980.8-1.1
84721.514215.140.8170.94-1.29
72418.377183.770.9571.1-1.51
61815.71571.121.29-1.76
52813.411134.111.3111.51-2.07
45111.458114.581.5341.76-2.42
3859.78797.871.7962.07-2.83
3298.36283.622.1022.42-3.31
2817.14271.422.4612.83-3.88
2406.10461.042.883.31-4.54
2055.19951.993.3813.89-5.33
1754.44544.453.9554.54-6.23
1503.8138.14.6145.3-7.27
1283.25432.545.4026.21-8.51
1092.77927.796.3267.27-9.97
942.38323.837.3778.49-11.6
802.02420.248.6859.97-13.7
691.74817.4810.05711.6-15.9
591.50915.0911.64913.4-18.4
501.2712.713.84215.9-21.8
441.11311.1315.79418.2-24.9
380.9539.5318.44621.2-29.1
330.8338.3321.10324.3-33.2
280.7147.1424.6228.3-38.8
250.6356.3527.68331.8-43.6
220.5565.5631.61736.4-49.8
190.4784.7836.77642.4-58.1
170.4374.3740.22746.3-63.5
140.3583.5849.10356.6-77.5
130.3183.1855.2863.5-87.2
110.2772.7763.46272.7-99.7
90.2392.3973.55284.8-116